Centre d'Information et de documentation du CRA Rhône-Alpes
CRA
Informations pratiques
-
Adresse
Centre d'information et de documentation
du CRA Rhône-Alpes
Centre Hospitalier le Vinatier
bât 211
95, Bd Pinel
69678 Bron CedexHoraires
Lundi au Vendredi
9h00-12h00 13h30-16h00Contact
Tél: +33(0)4 37 91 54 65
Mail
Fax: +33(0)4 37 91 54 37
-
Détail de l'auteur
Auteur A. J. R. DOYLE |
Documents disponibles écrits par cet auteur (2)
Faire une suggestion Affiner la recherche
Development of kinaesthetic sensitivity and motor performance in children / J. M. ELLIOTT in Developmental Medicine & Child Neurology, 30-1 (February 1988)
[article]
Titre : Development of kinaesthetic sensitivity and motor performance in children Type de document : Texte imprimé et/ou numérique Auteurs : J. M. ELLIOTT, Auteur ; Kevin CONNOLLY, Auteur ; A. J. R. DOYLE, Auteur Année de publication : 1988 Article en page(s) : p.80-92 Langues : Anglais (eng) Index. décimale : PER Périodiques Permalink : https://www.cra-rhone-alpes.org/cid/opac_css/index.php?lvl=notice_display&id=773
in Developmental Medicine & Child Neurology > 30-1 (February 1988) . - p.80-92[article] Development of kinaesthetic sensitivity and motor performance in children [Texte imprimé et/ou numérique] / J. M. ELLIOTT, Auteur ; Kevin CONNOLLY, Auteur ; A. J. R. DOYLE, Auteur . - 1988 . - p.80-92.
Langues : Anglais (eng)
in Developmental Medicine & Child Neurology > 30-1 (February 1988) . - p.80-92
Index. décimale : PER Périodiques Permalink : https://www.cra-rhone-alpes.org/cid/opac_css/index.php?lvl=notice_display&id=773 Measurement of kinaesthetic sensitivity / A. J. R. DOYLE in Developmental Medicine & Child Neurology, 28-2 (April 1986)
[article]
Titre : Measurement of kinaesthetic sensitivity Type de document : Texte imprimé et/ou numérique Auteurs : A. J. R. DOYLE, Auteur ; Kevin CONNOLLY, Auteur ; J. M. ELLIOTT, Auteur Année de publication : 1986 Article en page(s) : p.188-193 Langues : Anglais (eng) Index. décimale : PER Périodiques Résumé : Two recent papers (Laszlo and Bairstow 1980, Bairstow and Laszlo 1981) have used the method of constant stimuli to measure kinaesthetic difference thresholds. If this method is used, however, certain constraints must be observed: these concern the values of the stimuli relative to the threshold, and the numbers of observations made at each value. Laszlo and Bairstow appear to have neglected these constraints, which must cast doubt on their results. In any case, the method of constant stimuli has largely been superseded by staircase techniques for threshold estimation, on grounds of economy of trials for a given level of accuracy in estimation. It is concluded, therefore, that the details of the method as described by Laszlo and Bairstow are unsuitable for testing kinaesthetic sensitivity, and that other methods are preferable. Permalink : https://www.cra-rhone-alpes.org/cid/opac_css/index.php?lvl=notice_display&id=612
in Developmental Medicine & Child Neurology > 28-2 (April 1986) . - p.188-193[article] Measurement of kinaesthetic sensitivity [Texte imprimé et/ou numérique] / A. J. R. DOYLE, Auteur ; Kevin CONNOLLY, Auteur ; J. M. ELLIOTT, Auteur . - 1986 . - p.188-193.
Langues : Anglais (eng)
in Developmental Medicine & Child Neurology > 28-2 (April 1986) . - p.188-193
Index. décimale : PER Périodiques Résumé : Two recent papers (Laszlo and Bairstow 1980, Bairstow and Laszlo 1981) have used the method of constant stimuli to measure kinaesthetic difference thresholds. If this method is used, however, certain constraints must be observed: these concern the values of the stimuli relative to the threshold, and the numbers of observations made at each value. Laszlo and Bairstow appear to have neglected these constraints, which must cast doubt on their results. In any case, the method of constant stimuli has largely been superseded by staircase techniques for threshold estimation, on grounds of economy of trials for a given level of accuracy in estimation. It is concluded, therefore, that the details of the method as described by Laszlo and Bairstow are unsuitable for testing kinaesthetic sensitivity, and that other methods are preferable. Permalink : https://www.cra-rhone-alpes.org/cid/opac_css/index.php?lvl=notice_display&id=612